UW CHEMISTRY NMR

Announcments & Equipment Logs

Usage

UPDATE ! AV300 : BACKUP BBO PROBE SHIMMED UP AND READY TO GO !

Dear All The ATMA probe has been sent for repairs and I immediately don’t know when it will return from the manufacturer.     In the meanwhile,  the Broad band BBO probe, which uses manual tuning/matching  in place of the automated system is now in the magnet. Although we are all rather used to the comfort of […]

Posted in Hardware, Spectrometer, Usage | No Comments »

UPDATE : DRX499 – SYSTEM IS BEHAVING (AGAIN !) NORMALLY

Dear DRX499 loyalists This time around, I think we have identified the operating system related issue and mitigated the same.   The system used to freeze up within a minute or two earlier but it is looking and behaving normally for about 20 minutes now, and that is a positive sign. The Best way to see […]

Posted in Spectrometer, Usage | No Comments »

UPDATE ! INSTRUMENT LOGBOOKS REVAMPED..

Dear Users This is a brief update on the topic of  flaky Logbook behavior.  Thanks to the immediate efforts of our department IT support,  the Logbooks are back in action. Here is a quick link to the Logbooks that you can bookmark : https://depts.washington.edu/chemwp/chemwpnmr/equipment-logs/ What more, there are two additional features I want to highlight […]

Posted in Spectrometer, Usage | No Comments »

UPDATE ! DRX499 – SYSTEM IS USABLE NOW..

Dear DRX499 patrons The computer system froze couple of times and we have done our part in reviving the same.  As I write this,  the spectrometer is usable as before but we will be closely watching the behavior, since we haven’t fully identified what caused the system freezes.   So, if that happens again, feel free […]

Posted in Hardware, Spectrometer, Usage | No Comments »

UPDATE ! NMR FACILITY BACK TO NORMAL

Hello Users Just now learned that the Bagley Hall water problem has been rectified.   The NMR facility calendar is open for reservation now. Thank you NMR Facility Manager 1/30/2021

Posted in Spectrometer, Usage | No Comments »

ALERT ! NMR FACILITY SHUTDOWN DUE TO WATER EMERGENCY

Physical Plant is working on a water supply emergency that is confined to Bagley Hall.  The building Administrator has ordered the NMR facility to be closed until further notice.  So, you won’t be able to block NMR time until the situation returns to normal. I have tentatively blocked off the calendar to emphasize this point. […]

Posted in Spectrometer, Usage | No Comments »

NOTE : INSTRUMENT LOGBOOK ISSUES

Hello NMR Users I recently learned of issues with posting messages in the instrument Log Books that is provided via a Web Page.   It is a strange ‘Catch 22’  situation where you could not have communicated the problem via a Log Book entry ! While we are looking into solutions after simulating the problems at […]

Posted in Software, Spectrometer, Usage | No Comments »

UPDATE – AV300 – PROBE TUNING ISSUES

There has been repeated reported reports, albeit only from a subset of users, that the ATMA probe tuning/matching is taking very long.   I want to first assure you that we are already working on possible ways to resolve this. Recap :  Historically all NMR probes were tuned/matched by hand and this is an important and […]

Posted in Hardware, Spectrometer, Usage | No Comments »

ALERT : NMR LAB TEMPERATURE ISSUES…BEING LOOKED INTO

Hello all You might have noticed that the NMR Lab i.e. Rm.37, Bagley was ‘generously warm’  today and in fact the thermostat was reading close to 86 F.  Over and above this high room temperature, we discovered that the control mechanism that keeps the room temperature from fluctuating wildly, is not functioning. The upshot: The […]

Posted in Spectrometer, Usage | No Comments »

UPDATE ! AV500 – SYSTEM READY FOR USE

The 13C channel tuning problem has been fixed.   I would like to emphasize the following:  ” please be gentle with the tuning and matching knobs; do not use excessive force and try to turn them beyond their stop position, ever ! ” Along with this, we have also made sure that the 1H channel tuning […]

Posted in Hardware, Spectrometer, Usage | No Comments »