{"id":325,"date":"2022-09-08T21:53:07","date_gmt":"2022-09-08T21:53:07","guid":{"rendered":"https:\/\/depts.washington.edu\/chnadmin\/?page_id=325"},"modified":"2022-09-08T22:08:55","modified_gmt":"2022-09-08T22:08:55","slug":"chn-mri-peripheral-equipment","status":"publish","type":"page","link":"https:\/\/depts.washington.edu\/chnadmin\/chn-mri-peripheral-equipment\/","title":{"rendered":"CHN-MRI Peripheral Equipment"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Documents for Grants<\/h2>\n<p><meta charset=\"utf-8\"><\/p>\n<li>You can download the current CHN-MRI Facilities document <a rel=\"noreferrer noopener\" href=\"https:\/\/depts.washington.edu\/chnadmin\/wordpress\/wp-content\/uploads\/2022\/09\/CHN-MRI_Facilities_2022-06-01.docx\" target=\"_blank\">here<\/a>. <\/li>\n<li>We are happy to provide a letter of support for any grant applications! Please email <a href=\"emailto:johnp@uw.edu\">John Pyles<\/a>. <\/li>\n<h2 class=\"wp-block-heading\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"333\" class=\"wp-image-328\" style=\"width: 500px;\" src=\"https:\/\/depts.washington.edu\/chnadmin\/wordpress\/wp-content\/uploads\/2022\/09\/CHN-ControlRoom.jpeg\" alt=\"\" srcset=\"https:\/\/depts.washington.edu\/chnadmin\/wordpress\/wp-content\/uploads\/2022\/09\/CHN-ControlRoom.jpeg 1500w, https:\/\/depts.washington.edu\/chnadmin\/wordpress\/wp-content\/uploads\/2022\/09\/CHN-ControlRoom-300x200.jpeg 300w, https:\/\/depts.washington.edu\/chnadmin\/wordpress\/wp-content\/uploads\/2022\/09\/CHN-ControlRoom-1024x683.jpeg 1024w, https:\/\/depts.washington.edu\/chnadmin\/wordpress\/wp-content\/uploads\/2022\/09\/CHN-ControlRoom-768x512.jpeg 768w, https:\/\/depts.washington.edu\/chnadmin\/wordpress\/wp-content\/uploads\/2022\/09\/CHN-ControlRoom-375x250.jpeg 375w, https:\/\/depts.washington.edu\/chnadmin\/wordpress\/wp-content\/uploads\/2022\/09\/CHN-ControlRoom-750x500.jpeg 750w, https:\/\/depts.washington.edu\/chnadmin\/wordpress\/wp-content\/uploads\/2022\/09\/CHN-ControlRoom-1140x760.jpeg 1140w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/h2>\n<h2 class=\"wp-block-heading\"><meta charset=\"utf-8\">Current Peripheral Equipment<\/h2>\n<ul class=\"wp-block-list\">\n<li><strong>Siemens Coils:<\/strong>\n<ul>\n<li>64 channel head\/neck<\/li>\n<li>32 channel head<\/li>\n<li>20 channel head\/neck<\/li>\n<li>spine<\/li>\n<li>flex coils<\/li>\n<\/ul>\n<\/li>\n<li><strong>Installed C2P Sequences:<\/strong>\n<ul>\n<li>CMRR Multiband BOLD &amp; Diffusion EPI<\/li>\n<li>MGH SMS<\/li>\n<li>MGH Navigator Guided T1\/T2<\/li>\n<li>MGH Multi-echo MPRAGE<\/li>\n<li>ABCD Protocols<\/li>\n<li>Delaware Brain EPI MRE<\/li>\n<li>UCL MPM (hMRI)<\/li>\n<li>MGH &#8211; gSlider, MIEPI, BlippedCAIPI, 3D_MRF<\/li>\n<li>UCLA PCASL<\/li>\n<li>HCP Protocols<\/li>\n<\/ul>\n<\/li>\n<li><strong>Visual Display:<\/strong>\n<ul>\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/www.crsltd.com\/tools-for-functional-imaging\/mr-safe-displays\/boldscreen-32-lcd-for-fmri\/\" target=\"_blank\">Cambridge Research Systems BOLDscreen 32<\/a><\/li>\n<\/ul>\n<\/li>\n<li><strong>Response Devices:<\/strong>\n<ul>\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/www.curdes.com\/mainforp\/interfaces\/birch-optical-interface-unit.html\" target=\"_blank\">Current Designs BIRCH Interface<\/a><\/li>\n<li>Current Designs &#8211; <a rel=\"noreferrer noopener\" href=\"https:\/\/www.curdes.com\/mainforp\/responsedevices\/hhsc-1x5-n4.html\" target=\"_blank\">PYKA<\/a>, <a rel=\"noreferrer noopener\" href=\"https:\/\/www.curdes.com\/mainforp\/responsedevices\/pyka-8-thumbs-disabled.html\" target=\"_blank\">PYKA Bi-Manual<\/a>, <a rel=\"noreferrer noopener\" href=\"https:\/\/www.curdes.com\/mainforp\/responsedevices\/hhsc-2x2.html\" target=\"_blank\">4 Button Bi-Manual<\/a>, <a rel=\"noreferrer noopener\" href=\"https:\/\/www.curdes.com\/mainforp\/responsedevices\/hhsc-2x1-cyl.html\" target=\"_blank\">2 Button Cylinder<\/a>, <a rel=\"noreferrer noopener\" href=\"https:\/\/www.curdes.com\/mainforp\/responsedevices\/hhsc-joy-6a.html\" target=\"_blank\">Joystick<\/a>, <a rel=\"noreferrer noopener\" href=\"https:\/\/www.curdes.com\/mainforp\/responsedevices\/hhsc-trk-2.html\" target=\"_blank\">Trackball<\/a>, Custom Slider<\/li>\n<\/ul>\n<\/li>\n<li><strong>Auditory Presentation:<\/strong>\n<ul>\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/www.optoacoustics.com\/medical\/optoactive\/features\" target=\"_blank\">Optoacoustics Optoactive II Noise Cancelling Headphones<\/a><\/li>\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/www.optoacoustics.com\/medical\/fomri-iii\/features\" target=\"_blank\">Optoacoustics FOMRI III Noise Cancelling Microphone<\/a><\/li>\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/www.sens.com\/products\/model-s14\/\" target=\"_blank\">Sensimetrics S14 Insert Earphones<\/a><\/li>\n<\/ul>\n<\/li>\n<li><strong>Head Stabilization:<\/strong>\n<ul>\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/www.pearl-technology.ch\/en\/multipad\" target=\"_blank\">Pearltech Multipad System<\/a><\/li>\n<\/ul>\n<\/li>\n<li><strong>Physiological Monitoring:<\/strong>\n<ul>\n<li>Siemens Wireless Pulse Oximeter, Respiratory Belt, &amp; EKG<\/li>\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/www.biopac.com\/\" target=\"_blank\">BIOPAC<\/a> &#8211; GSR &amp; electrical stimulation (expandable to any BIOPAC sensors!)<\/li>\n<\/ul>\n<\/li>\n<li><strong>Eyetracking:<\/strong>\n<ul>\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/www.sr-research.com\/fmri-meg-systems\/\" target=\"_blank\">SR Research Eyelink 1000 Plus<\/a> &#8211; Eyetracker stays in bore and can be used for participant monitoring<\/li>\n<\/ul>\n<\/li>\n<li><strong>Participant Monitoring:<\/strong>\n<ul>\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/nousimaging.com\/solutions\/\" target=\"_blank\">FIRMM<\/a> real-time motion monitoring<\/li>\n<li>Bore Camera (foot side)<\/li>\n<li>Bore Camera (head side, to be installed Fall 2022)<\/li>\n<\/ul>\n<\/li>\n<li><strong>Experiment Presentation Computers &amp; Software:<\/strong>\n<ul>\n<li>Windows: Presentation, E-Prime 3.0, Psychophysics Toolbox, PsychoPy<\/li>\n<li>Mac: Psychophysics Toolbox, PsychoPy, Matlab<\/li>\n<li>Linux (Ubuntu): To be installed Fall 2022<\/li>\n<li>Laptop: Researchers can bring a laptop and connect to all devices<\/li>\n<\/ul>\n<\/li>\n<li><strong>Testing Rooms:<\/strong>\n<ul>\n<li>All testing rooms equipped with Windows PC with E-Prime 3.0.<\/li>\n<li>B120B: Round conference table &amp; computer table<\/li>\n<li>B120C: Family waiting\/testing with couch, rocking chair, white noise maker, dimming lamp, and computer table<\/li>\n<\/ul>\n<\/li>\n<li><strong>Safety &amp; Participant Comfort:<\/strong>\n<ul>\n<li>Large Waiting Room<\/li>\n<li>Guest Wifi<\/li>\n<li>Secure lockers and safe for personal items<\/li>\n<\/ul>\n<\/li>\n<li><strong>Mock Scanner:<\/strong>\n<ul>\n<li>Custom PST Deluxe MRI Simulator<\/li>\n<li>Replicate Siemens 64ch Mock Head Coil<\/li>\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/pstnet.com\/products\/motrak\/\" target=\"_blank\">MoTrak<\/a> motion tracking system<\/li>\n<li><a rel=\"noreferrer noopener\" href=\"https:\/\/pstnet.com\/products\/simfx\/\" target=\"_blank\">SimFx<\/a> MRI auditory simulation built into mock scanner <\/li>\n<li>In-Bore participant monitoring camera<\/li>\n<li>Windows PC with Presentation, E-Prime 3.0, Psychophysics Toolbox, Matlab<\/li>\n<li>Display matching visual angle and resolution of real MRI<\/li>\n<li>Current Designs mock response devices<\/li>\n<li>Trigger simulator (to be installed Fall 2022)<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/depts.washington.edu\/chnadmin\/wordpress\/wp-content\/uploads\/2022\/09\/MockMRI-1024x768.jpg\" alt=\"\" class=\"wp-image-329\" srcset=\"https:\/\/depts.washington.edu\/chnadmin\/wordpress\/wp-content\/uploads\/2022\/09\/MockMRI-1024x768.jpg 1024w, https:\/\/depts.washington.edu\/chnadmin\/wordpress\/wp-content\/uploads\/2022\/09\/MockMRI-300x225.jpg 300w, https:\/\/depts.washington.edu\/chnadmin\/wordpress\/wp-content\/uploads\/2022\/09\/MockMRI-768x576.jpg 768w, https:\/\/depts.washington.edu\/chnadmin\/wordpress\/wp-content\/uploads\/2022\/09\/MockMRI-1536x1152.jpg 1536w, https:\/\/depts.washington.edu\/chnadmin\/wordpress\/wp-content\/uploads\/2022\/09\/MockMRI-2048x1536.jpg 2048w, https:\/\/depts.washington.edu\/chnadmin\/wordpress\/wp-content\/uploads\/2022\/09\/MockMRI-375x281.jpg 375w, https:\/\/depts.washington.edu\/chnadmin\/wordpress\/wp-content\/uploads\/2022\/09\/MockMRI-750x563.jpg 750w, https:\/\/depts.washington.edu\/chnadmin\/wordpress\/wp-content\/uploads\/2022\/09\/MockMRI-1140x855.jpg 1140w, https:\/\/depts.washington.edu\/chnadmin\/wordpress\/wp-content\/uploads\/2022\/09\/MockMRI-108x81.jpg 108w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Documents for Grants You can download the current CHN-MRI Facilities document here. We are happy to provide a letter of support for any grant applications! Please email John Pyles. Current Peripheral Equipment Siemens Coils: 64 channel head\/neck 32 channel head 20 channel head\/neck spine flex coils Installed C2P Sequences: CMRR Multiband BOLD &amp; Diffusion EPI&#8230;<\/p>\n<div><a class=\"more\" href=\"https:\/\/depts.washington.edu\/chnadmin\/chn-mri-peripheral-equipment\/\">Read more<\/a><\/div>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"templates\/template-no-hero.php","meta":{"footnotes":""},"class_list":["post-325","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/depts.washington.edu\/chnadmin\/wp-json\/wp\/v2\/pages\/325","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/depts.washington.edu\/chnadmin\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/depts.washington.edu\/chnadmin\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/depts.washington.edu\/chnadmin\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/depts.washington.edu\/chnadmin\/wp-json\/wp\/v2\/comments?post=325"}],"version-history":[{"count":2,"href":"https:\/\/depts.washington.edu\/chnadmin\/wp-json\/wp\/v2\/pages\/325\/revisions"}],"predecessor-version":[{"id":331,"href":"https:\/\/depts.washington.edu\/chnadmin\/wp-json\/wp\/v2\/pages\/325\/revisions\/331"}],"wp:attachment":[{"href":"https:\/\/depts.washington.edu\/chnadmin\/wp-json\/wp\/v2\/media?parent=325"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}