Data can come off the scanner with arbitrary header information and the subject might not be properly position. So for each subject we start by defining a coordinate frame where 0,0,0 is at the anterior commissure, the anterior and posterior commissure are in the same X and Z planes, and the mid-line is centered in the image. Bob Dougherty wrote a nice tool to help with this. See [https://github.com/vistalab/vistasoft/blob/master/mrAnatomy/VolumeUtilities/mrAnatAverageAcpcNifti.m mrAnatAverageAcpcNifti]. The subject's T1-weighted image should be ac-pc aligned, resliced (preserving its resolution), and saved in the subject's anatomy directory.
 
Data can come off the scanner with arbitrary header information and the subject might not be properly position. So for each subject we start by defining a coordinate frame where 0,0,0 is at the anterior commissure, the anterior and posterior commissure are in the same X and Z planes, and the mid-line is centered in the image. Bob Dougherty wrote a nice tool to help with this. See [https://github.com/vistalab/vistasoft/blob/master/mrAnatomy/VolumeUtilities/mrAnatAverageAcpcNifti.m mrAnatAverageAcpcNifti]. The subject's T1-weighted image should be ac-pc aligned, resliced (preserving its resolution), and saved in the subject's anatomy directory.
 
+
=Freesurfer Segmentation=
<syntaxhighlight lang="python">
+
test
+
</syntaxhighlight>
+

Revision as of 19:49, 14 August 2015

We collect a high resolution T1-weighted image on every subject, and use this image to define the coordinate space for all subsequent analyses. This section describes the processing steps for a subject's T1-weighted anatomy and should be performed before analyzing the rest of their MRI data.

AC-PC Alignment

Data can come off the scanner with arbitrary header information and the subject might not be properly position. So for each subject we start by defining a coordinate frame where 0,0,0 is at the anterior commissure, the anterior and posterior commissure are in the same X and Z planes, and the mid-line is centered in the image. Bob Dougherty wrote a nice tool to help with this. See mrAnatAverageAcpcNifti. The subject's T1-weighted image should be ac-pc aligned, resliced (preserving its resolution), and saved in the subject's anatomy directory.

Freesurfer Segmentation