UW CHEMISTRY NMR

Announcments & Equipment Logs

Software

UPDATE ! GG500 – ICON QUEUE GOT RESET (MYSTERIOUSLY )

Here is the latest.   Someone or ‘some process’  reset the earlier Icon NMR session and restarted a fresh one.  Upshot is that, the earlier submitted experiments are washed away. Please resubmit your experiments, if yours is part of the cohort that got aborted. NMR Facility 6.31 pm 5.15.25

Posted in Software, Spectrometer | 1 Comment »

ALERT : GG500 – AUTOMATION QUEUE WILL BE REFRESHED TOMORROW

Dear Users The graphical IconNMR interface is behaving abnormally such that, a new user is not able to login to queue samples.  Even the administrator account cannot take control of the queue currently.  But the already submitted experiments are proceeding without an issue. To avoid a disruption to the already submitted runs, including the long […]

Posted in Software, Spectrometer | No Comments »

UPDATE – GG500 : ICONNMR FULL WORKTAG ACCESS RESTORED

You should be able to see all the Worktags belonging to  your Netid now, via a pull down menu.  Please let us know, if you see otherwise. NMR Facility 10.30.24

Posted in NMR Facility Usage, Software, Spectrometer, Usage | No Comments »

NOTE – GG500 : PROBLEM ACCESSING MULTIPLE BUDGET TAGS

We are aware of the software glitch, that does not allow you to choose budget/Worktags from the pull down menu in the Automation window.  It only displays the first Worktag from the list.  We are working on a solution and will update once it is resolved. NMR Facility 10.30.24

Posted in Software, Spectrometer | No Comments »

UPDATE : NEO500 – SYSTEM ONLINE AFTER SOFTWARE MAINTENANCE

The computer system is upgraded along with the NMR software.  The sporadic crash of Topspin noticed last week, should be gone with this upgrade. It will take a few minutes before the data appears in FTP server phoenix.chem.washington.edu You should also receive a completion email as well as a PDF snapshot of your spectrum upon […]

Posted in Hardware, Software, Spectrometer, Usage | No Comments »

UPDATE : GG500 – Selenium 77 TESTED OK

Some users had mentioned that 77Se is not working as expected, recently.  It is tested to be running OK as of today. When you drive the instrument interactively, use the command phrase : rpar 77Se.amr all For additional convenience, we have a macro to do the above and setup the correct parameters.  Just enter : […]

Posted in Software, Spectrometer, Usage | No Comments »

ALERT ! GG500 – DOWN DUE TO SOFTWARE ISSUE

Please do not reserve any time before we release the instrument with a fix in place. Those of you who have reserved time as of now may have to delete the reservation depending on how long the system will be down. More updates will be forthcoming. NMR Facility

Posted in Software, Spectrometer | No Comments »

GG500 : AUTOMATION QUEUE IS UP

Sorry for the unexpected delay.  Please queue up your samples.   We are aware of some sample injection issues that pops up randomly. We are working to address the same as soon as we can. NMR FACILITY

Posted in Hardware, Software, Spectrometer | No Comments »

GG500 – HEADS UP – QUEUE WILL STOP FROM 12 NOON TO 2 PM – SOFTWARE WORK

Please do not queue anything that will start acquisition at 12 noon.  Once the queue is restored, we will send another broadcast. NMR Facility

Posted in Software, Spectrometer | No Comments »

NOTE ! GG500 – WILL ENTER ICONNMR AUTOMATION TOMORROW – FRI 14TH

The Topspin ICONNMR interface will be deployed starting noon tomorrow i.e. Friday, the 14th.   It is very similar to the NEO500 interface.  Here are points that are unique to GG500. Access : The system will be in Full IconNMR Automation mode from Friday morning 10 AM of a given week and continue till 10 AM […]

Posted in Hardware, NMR Facility Usage, Software, Spectrometer, Usage | No Comments »

Item Categories

Archives