UW CHEMISTRY NMR

Announcments & Equipment Logs

June, 2017

AV301 – UDRIVE – REFRESHER..

Dear Users :  Sorry for not including the web page links that outline UDRIVE storage from AV301, yesterday. Here are the two links : TOPSPIN environment after UDRIVE : Chemistry NMR : After UDRIVE – What changes in TOPSPIN graphical interface How to work with NMR data that is collected into your own UDRIVE UDRIVE […]

Posted in Uncategorized | No Comments »

REMINDER ! AV301 – UDRIVE TRANSITION – PHASE 1 IS OPERATIONAL NOW

Users are requested to take note that, beginning 5 AM today i.e. Wednesday, 28th June ’17, the AV301 system is transitioned to UW UDRIVE storage.  Users MUST CREATE DATASETS in their respective UDRIVE folders.  If you have not done so already, please refer to the following links that guide you through this transition. NOTE :  […]

Posted in Datasets, Host Computer, Usage | No Comments »

ALERT ! AV301 – 31P TUNE/MATCH ISSUE

We are looking into the problem of ATMA and ATMM failing for the 31P selection.  Initial tests show that the symptom might spread to the 13C channel with some lock solvents.  The probe needs to be pulled out for further repairs. Once a back up plan is in place, we will announce the probe swap […]

Posted in Hardware, Spectrometer | No Comments »

UPDATE ! AV300 – ATMA AND ATMM STABLE

Quick recap :  Many users found that 1H tuning/matching using ATMA or ATMM command did not behave as expected (either a flat wobble curve or no response to turning the tuning/matching capacitors in ATMM). Remedial measures are applied now. I expect the tuning/matching to behave properly for most of the commonly used lock solvents.  Please […]

Posted in Hardware, Software, Spectrometer | No Comments »

ATTENTION ! : INTRODUCING NEW STORAGE PARADIGM – UDRIVE

Moving with the times, we wanted to evolve a new storage solution that makes it robust, easy and secure to store and retrieve NMR data from the spectrometers. Such a solution should also be maintenance free, pretty much. This will free us all from the uncertainties of failing hardware and constant need for intervention from […]

Posted in Uncategorized | No Comments »

UPDATE ! AV301 – LOGIN ISSUE IS RESOLVED

The login issue that users noticed is linked to a network outage problem with UW Udrive resource.  As I write this, IT connect has not yet resolved this. So, we have fenced off the cause of the frozen login at our end and users can now login to the system as before. The UDRIVE cloud […]

Posted in Host Computer, Operating System | No Comments »

UPDATE ! AV500 – TOPSHIM WORKING PROPERLY

All good to run Topshim.  Please let us know if it still has issues. Thanks NMR Facility Manager 6/2/17

Posted in Software, Spectrometer | No Comments »

ALERT : AV500 – TOPSHIM NOT FUNCTIONAL

Several of you have noticed that Topshim was failing.   Currently,  when you run Topshim, the software will not complain but the shims don’t change to give you a better lineshape or resolution. I have taken a preliminary look and will continue troubleshooting to run the problem to ground.  As of now, you have to touch […]

Posted in Hardware, Spectrometer | No Comments »

Item Categories

Archives