UW CHEMISTRY NMR

Announcments & Equipment Logs

Usage

APPEAL – NEO500 : LET US KEEP THE HOUSE CLEAN !

Dear NEO Users Appeal 1 : the problem of “Orphaned NMR Tubes” Please take a moment to behold the ‘status quo’  of samples near the instrument that I recorded yesterday. Now, this is over and above all the holder positions of the sample Carousel being completely occupied during the time of the picture snapping. With […]

Posted in NMR Facility Usage, Spectrometer, Usage | No Comments »

NEO500 – REMINDER – PEACEFUL COEXISTENCE !

Dear NEO500 users Owing to the true ‘walk-on’  nature of the NEO500 SYSTEM, we may not be compelled to access the NMR Reservation Page for this instrument.   I wanted to send you this gentle reminder in connection with the same. Please note that, you have a near live view of the NEO500 automation queue, which […]

Posted in NMR Facility Usage, Software, Spectrometer, Usage | No Comments »

GG500 – SYSTEM OPTIMIZATION UPDATE

Dear All Standard parameter sets for three nuclei have been added. For 77Se NMR, on the command line, type: rpar 77Se all and press Return For 7Li NMR, on the command line, type:  rpar 7Li all and press Return For 11B NMR,  on the command line, simply type :  boron AND press Return Please remember […]

Posted in Software, Spectrometer, Usage | No Comments »

NEO500 SAFETY : PLEASE TAKE NOTE !

Dear Users Please pay attention to the following picture.   The automatic sample loading Carousel in NEO500 is equipped with a Safety Mechanism that detects sample tubes that are too tall and prevents them from crashing into the sample Inject Aluminum casing and break. This is a great feature that protects the Autosampler from damage […]

Posted in Hardware, NMR Facility Usage, Spectrometer, Usage | No Comments »

UPDATE ! GG500 – OPEN FOR USE WITH NEW iPROBE

Dear Users The NEW iProbe is installed and tested to its minimal functionality so that you can start running your routine spectroscopy without further waiting. But, let me emphasize the following points, which you need to take note of : Recall your detailed training on the 300 systems.  You will need the same skill set […]

Posted in Hardware, Spectrometer, Usage | No Comments »

ALERT ! PHEONIX FTP SERVER IS DOWN…

Dear Users You might be having issues connecting to Phoenix server from yesterday evening to download the 500 NMR data.   We are aware of this and looking into it. Hopefully this will be resolved soon and I will post an update once that happens. NMR Facility Manager 5/2/23

Posted in Software, Spectrometer, Usage | No Comments »

UPDATE ! GG500 – NEW iProbe INSTALLATION IN PROGRESS

Dear Users      First,  from your feedback : A clear majority of you want to operate the GG500 instrument with the new iProbe using the traditional Topspin Interface, where you can freely interact with the system and do as you please (with the watchful assistance of me and Adrienne, of course, so that no inadvertent […]

Posted in Hardware, Software, Spectrometer, Usage | No Comments »

REMINDER (2) : GG500 – SOFTWARE INTERFACE POLL

Dear Users For those of you who missed some action on what this title implies, here is a quick link to bring you up to speed. We have a brand new BBFO fully automated probe (i.e. automatic tuning/matching, locking/shimming)  that is ready to replace the aging TXO-1H-19F probe that is coupled to the GG500 console. […]

Posted in Hardware, Spectrometer, Uncategorized, Usage | No Comments »

UPDATE : GG500 : 13C PARAMETER SET BEHAVES OK NOW

Dear Users First of, sorry for the disruption caused for those of you who have come to depend on the default parameter settings for your 13C routine runs.   I take sole responsibility for the same, since I was test running a ‘multi acquisition’ version of the 13C NMR with temperature variation in-built, to address a […]

Posted in Software, Spectrometer, Usage | No Comments »

REMINDER ! GG500 – SOFTWARE SNAP POLL and IMMINENT PROBE UPGRADE

Dear Users For the benefit of those of you who might have missed my last call on the topic, please click on the link below. SNAP POLL: GG500’s NEW BBFO iProbe – SOLICITING YOUR INPUT   I renew the call above and request you to email to : rajanp@uw.edu about which of the three software […]

Posted in Hardware, NMR Facility Usage, Software, Spectrometer, Usage | No Comments »