ALERT ! AV301 – SYSTEM DOWN DUE TO SAMPLE HANDLING PROBLEM

A user sample has broken inside the magnet and the sample Lift function is compromised. I will post an update once the broken sample is removed and the function tested to be normal again. NMR Facility Manager 10/28/2021

Posted in Hardware, Spectrometer, Usage | No Comments »

NOTE ON GG500 : TBI PROBE (RE)INTRODUCED !

Dear Users Many of you might recall the look and feel of this Triple Resonance TBI probe when it was placed with the AV500 system, before GG500 was born.   It won’t hurt to have a refresher and familiarize oursleves with this probe, which is now paired with GG500 console. 1H NMR : The picture below […]

Posted in Hardware, Spectrometer, Usage | No Comments »

UPDATE ! AV301 : SAMPLE LANDING AND SPINNING ISSUES RESOLVED !

Hello Users ! We have done a ‘deep cleaning’  of the sample handling system yesterday and the results speak for themselves.  The sample lands properly and it is detected correctly by the system. The Sample Spinning settles to its target rate pretty quickly now. We also have shimmed up the system and so it should […]

Posted in Hardware, Spectrometer, Usage | No Comments »

UPDATE ! GG500 – IS BACK ONLINE FOR REGULAR USE…

Dear Users GG500 is now ready for routine use with the TBI triple resonance probe in place, calibrated and optimzied. I am also glad to add that the VT  control is completely restored now so that you can run temperature variation experiments.  The nominal range is about -10 C to 70C but I will give […]

Posted in Hardware, Spectrometer, Usage | No Comments »

UPDATE : GG500 – DELAYED TILL TOMORROW..

Dear Users Unfortunately the instrument is not yet ready for regular use but we hope that it should be back in regular use by noon of tomorrow, Tuesday the 12th. Sorry for this delay. NMR Facility Manager 10/11/2021

Posted in Hardware, Spectrometer | No Comments »

ALERT ! GG500 – IMMINENT PROBE CHANGE- BBO to TBI

Hello Users We will be replacing the current double resonance BBO Probehead with the triple resonance TBI Probehead, on Monday, the 11th.  The instrument will be busy for this purpose, roughly for 3 hours beginning 10 AM on that day.  This is a quick note.  I will follow this with another later, that will provide […]

Posted in Hardware, Spectrometer | No Comments »

FACILITY UPDATE ! ALL SYSTEMS BACK TO NORMAL – 17 Sep 2021

NMR machines are ready for use.  Vitals have been checked and they are OK.  Feel free to communicate any abnormal behavior, just in case. The FTP server is up and running also. NMR Facility Manager 9/17/2021

Posted in Hardware, Software, Spectrometer, Usage | No Comments »

AN APPEAL : HANDLING BROKEN SAMPLES..

Hello NMR users In the unavoidable situation where a sample tube breaks on the bench (far better a situaion than it breaking inside the magnet !),  please dispose off the broken tube, shards, etc. only in the Sharps container that we provided.  One is on the wall next to the double doors that lead to […]

Posted in Spectrometer, Usage | No Comments »

UPDATE : AV500 – SHIM SYSTEM TAMED – MOSTLY

Dear Users I mentioned last week that a couple of hardware related issues need addressing and this is an update about the first and foremost of them :  getting consistent results from Topshim method of shimming for all Lock Solvents.   The root cause for the sporadic failure of Topshim, especially for weak lock signals […]

Posted in Hardware, NMR Applications, Spectrometer, Usage | No Comments »

UPDATE ! : ALL NMR SYSTEMS ARE REVIVED BACK

Dear Users Systems are ready for use.   As to the Power being pulled at 3.30 pm yesterday i.e. earlier than announced,  everyone was taken by surprise including the building co-ordinators.     Indeed it was unexpected but we couldn’t do much about it ! Good Day NMR Facility Manager 8/14/2021

Posted in Spectrometer, Usage | No Comments »