ALERT – AV700 : SYSTEM DOWN DUE TO VT ISSUES
By now familiar but ongoing issue with the VT cooling system is forcing an interruption once again today. We will work on an alternative and I am hopeful that the instrument can be released for regular use by tomorrow. Please look for further updates. NMR Facility Manager 7/19/2018
Posted in Hardware, Spectrometer | No Comments »
ALERT ! AV500 – PROBE HAS BEEN CHANGED
Since I discovered today morning that the VT dewar in the probe is compromised, I had to replace the BBI probe with the a different probe : Current probe head : TXI- 1H {13C, 15N} – Z gradient This is a triple resonance probe that is capable of handling 1H, 13C and 15N detection only. […]
Posted in Hardware, Spectrometer | No Comments »
UPDATE ! AV500 – SYSTEM NORMAL WITH BBI PROBE IN PLACE
NEW PROBEHEAD IN PLACE ! CURRENT PROBE : BBI 1H {X} – Z gradient DEFAULT SHIM SET : stdbbi Temperature range : -100 C to +70 C (for the former, special low T setup is needed. Contact for further details) PLEASE USE TOPSHIM FOR GETTING THE BEST RESOLUTION AND LINESHAPE Questions/Comments/Help ? : Please contact […]
Posted in Hardware, Spectrometer | No Comments »
ALERT ! AV500 – POSSIBLE PROBE CHANGE – VT DEWAR DAMAGED
The VT dewar inside the probe has been compromised and so you CANNOT run Variable Temperature experiments currently. ONLY nominal room temperature experiments are allowed at this point. We will most probably place a different probehead in place of the current HCP-Z Gradient probehead while the current probehead is serviced. We will try to do […]
Posted in Hardware, Spectrometer | No Comments »
UPDATE – AV300 : LOCK SYSTEM NORMAL
All good to go. Please let us know via log book, if there is still any issues you notice. Thank you NMR Facility Manager 6/27/2018
Posted in Hardware, Spectrometer | No Comments »
ALERT ! – AV300 : LOCK MALFUNCTION WILL BE FIXED TODAY BEFORE NOON
We are aware of the Auto Lock function having issues. In a few moments this will be addressed and an update will be given about the outcome. Stay tuned. NMR Facility Manager 6/27/2018
Posted in Hardware, Spectrometer | No Comments »
UPDATE ! AV700 : SYSTEM IS RELEASED FOR USE – PLEASE READ
The system is ready for normal use. Nevertheless, the VT system test is still being conducted in parallel in such a way that the users’ runs are not affected. As before, the LN2 tank you see is the source of the N2 gas, which is used as part of the troubleshoot process. The supply from […]
Posted in Hardware, Spectrometer | No Comments »
ALERT ! AV700 USERS : SYSTEM WILL BE DOWN FOR VT SYSTEM TROUBLESHOOT
Please wait further updates as to when the system will be back on line. NMR Facility Manager 6/12/2018
Posted in Hardware, Spectrometer | No Comments »
ALERT ! AV301 – SYSTEM DOWN DUE TO COMPUTER ISSUE
We are working actively to resolve the issue and will post an update once the task is competed. Other than the ‘udrive’ mounting problem, we are also aware of the acquisition error messages that was noticed by users. Hopefully, both these error conditions will be resolved at the same time. NMR Facility Manager 6/5/2018
Posted in Hardware, Spectrometer | No Comments »
AV700 – UPDATE ON VT SYSTEM STATUS
As part of an ongoing investigation of the ultra low temperature chiller system, users are alerted to the following. You will notice a Liquid Nitrogen Dewar sitting next to the Aluminum staircase. The N2 gas derived from this tank is used currently to run the VT system. This setup is transparent to the way VT […]
Posted in Spectrometer, Usage | No Comments »