UPDATE ! NEO500 – AUTOMATION QUEUE RESUMED AFTER MAINTENANCE

Users Due apologies for the delay in resuming the queue this morning (we posted end time as 8 AM).   But the maintenance is complete and the system is ready to receive samples. NMR FACILITY 12/4/24

Posted in Hardware, Spectrometer | No Comments »

NOTE : GG500 – READJUSTED SCHEDULE FOR THE HOLIDAYS THIS WEEK

The system will continue on Automation mode through the week and return to interactive session after the Thanksgiving longweekend i.e. on Monday, Dec.  2nd. System will be in interactive mode through next week and get back to the Automation routine on Dec. 6, Friday. NMR Facility 11.26.24

Posted in NMR Facility Usage, Spectrometer, Usage | No Comments »

UPDATE : 700 NMR ARRIVAL – ROOM 37, BAG

Here’s the latest.  The magnet legs have been moved to the assigned location today. The magnet itself will be moved into Rm.37, tomorrow morning.  We will notify of any changes promptly. NMR Facility 11.18.24

Posted in Hardware, Spectrometer | No Comments »

UPDATE : GETTING READY FOR THE ARRIVAL OF 700 NMR

Users Most of you would have noticed that the corner of Rm. 37 (NMR lab) has been slowly filling with the electronics and parts, which is a precursor to the full installtion of a 700 MHz NMR machine within the premises. An engineer is on site today making preparations for moving the NMR magnet to […]

Posted in Hardware, Spectrometer, Usage | No Comments »

UPDATE – GG500 : ICONNMR FULL WORKTAG ACCESS RESTORED

You should be able to see all the Worktags belonging to  your Netid now, via a pull down menu.  Please let us know, if you see otherwise. NMR Facility 10.30.24

Posted in NMR Facility Usage, Software, Spectrometer, Usage | No Comments »

NOTE – GG500 : PROBLEM ACCESSING MULTIPLE BUDGET TAGS

We are aware of the software glitch, that does not allow you to choose budget/Worktags from the pull down menu in the Automation window.  It only displays the first Worktag from the list.  We are working on a solution and will update once it is resolved. NMR Facility 10.30.24

Posted in Software, Spectrometer | No Comments »

UPDATE : NEO500 – SYSTEM ONLINE AFTER SOFTWARE MAINTENANCE

The computer system is upgraded along with the NMR software.  The sporadic crash of Topspin noticed last week, should be gone with this upgrade. It will take a few minutes before the data appears in FTP server phoenix.chem.washington.edu You should also receive a completion email as well as a PDF snapshot of your spectrum upon […]

Posted in Hardware, Software, Spectrometer, Usage | No Comments »

ALERT ! GG500 – AUTOMATION QUEUE RESTORED FROM FAILED STATE

Based on feedback, a user might have tripped the red safety lever on the Carousel yesterday evening leading to an ‘abort’ state of the Automation queue.  The queue has been restored this morning and reset to the first sample holder which encountered the failure.  Please calibrate your expectations of finishing times for your samples submitted […]

Posted in Hardware, Spectrometer | No Comments »

UPDATE : GG500 – Selenium 77 TESTED OK

Some users had mentioned that 77Se is not working as expected, recently.  It is tested to be running OK as of today. When you drive the instrument interactively, use the command phrase : rpar 77Se.amr all For additional convenience, we have a macro to do the above and setup the correct parameters.  Just enter : […]

Posted in Software, Spectrometer, Usage | No Comments »

UPDATE ! AV300 – SYSTEM BACK TO NORMAL

We resolved the original issue that was related to Mains power supply to the whole console.  We therefore don’t expect any functional changes in the system. But, do feel free to let us know if you observe anything abnormal.  The instrument is open for reservation. NMR Facility 10/23/24

Posted in Hardware, Spectrometer | No Comments »