UPDATE ! AV500 – TOPSHIM FUNCTIONALITY IS BACK
You can use the Topshim shimming routine on all deutero solvents as before. We will keep a close eye to see if anything is compromised again but, tests thus far indicate that the functionality is back on track. Please post a message in the log as soon as you notice something amiss and thanks. NMR […]
Posted in Spectrometer, Usage | No Comments »
ALERT ! AV300 : X – CHANNEL MALFUNCTION
The X-channel i.e. 13C and 31P, etc. is not functional. We have identified the most probable cause to be a faulty circuit board but it’s fix may take some time. Most probably a replacement unit will need to be obtained and that might take a few days. Since the 1H is the predominantly used nucleus […]
Posted in Hardware, Spectrometer, Usage | No Comments »
UPDATE ! DRX499 – CURRENT STATUS
Since there is still quite a few loose ends to tie up before the merged 500 MHz console is declared open, the existing DRX499 is back in operation as before. After this note, I will proceed directly to introduce the merged console to you, once it is confirmed to be functional in every respect. Thank […]
Posted in Hardware, Spectrometer, Usage | No Comments »
PLEASE READ ! DRX499 – IN REINCARNATED FORM
Many of you might have noticed an anteroom on the right, when you enter the NMR lab Room : 37 (it has a room number : 33, Bagley Hall). The more inquisitive among you might also have seen an NMR instrument in that space. This instrument originally belongs to Prof. Gabriele Varani of our department […]
Posted in Hardware, Spectrometer, Usage | No Comments »
ATTENTION USERS ! – SPECIALIZED TRAINING PLANS – PLEASE READ !
Over and above the simple but minimal training that is provided by the facility for the new users, we always recognized the need for training you in some special tasks such as how to properly maneuver the Lock facility or how to Shim by hand when Topshim fails, to site as examples. We are finally […]
Posted in NMR Applications, Spectrometer, Usage | No Comments »
UPDATE ! DRX499 – BBO – Z Gradient probe is in place…
Please remember to load the default shim set : stdbbo before setting up the experiment. NMR Facility Manager 8/6/2018
Posted in Hardware, Spectrometer, Usage | No Comments »
UPDATE : AV300 – PROGRESS WITH UDRIVE MIGRATION – BUT NOT READY YET
A few more lose ends to tie up before you will be ready to access the UDRIVE, similar to AV301. But the needed work will be done remotely without disrupting the regular use of the spectrometer. I will post another heads up message when we say it’s ready. In the interim, your data collection protocol […]
Posted in Software, Spectrometer, Usage | No Comments »
ALERT ! AV300 – UDRIVE UPGRADE SCHEDULED FOR TOMORROW
The Operating System and associated components will be upgraded starting tomorrow morning 9 am i.e. Tuesday, 31st of July ’18. Assuming that everything goes well, the interface you will see from 12 noon will be similar to the one on AV301. Also note that the data from then on will be directly written into your […]
Posted in Spectrometer, Usage | No Comments »
UPDATE – AV700 : SYSTEM OPEN FOR USE
Alternative arrangement for VT control is in place. Please post a message in the log book, if you notice abnormal behavior. Thank you for your cooperation. NMR Facility Manager 7/20/2018
Posted in Spectrometer, Usage | No Comments »
AV700 – UPDATE ON VT SYSTEM STATUS
As part of an ongoing investigation of the ultra low temperature chiller system, users are alerted to the following. You will notice a Liquid Nitrogen Dewar sitting next to the Aluminum staircase. The N2 gas derived from this tank is used currently to run the VT system. This setup is transparent to the way VT […]
Posted in Spectrometer, Usage | No Comments »