UPDATE ! AV500 – SYSTEM NORMAL WITH BBI PROBE IN PLACE

NEW PROBEHEAD IN PLACE ! CURRENT PROBE :  BBI 1H {X} – Z gradient DEFAULT SHIM SET : stdbbi Temperature range : -100 C to +70 C (for the former, special low T setup is needed. Contact for further details) PLEASE USE TOPSHIM FOR GETTING THE BEST RESOLUTION AND LINESHAPE Questions/Comments/Help ? :  Please contact […]

Posted in Hardware, Spectrometer | No Comments »

ALERT ! AV500 – POSSIBLE PROBE CHANGE – VT DEWAR DAMAGED

The VT dewar inside the probe has been compromised and so you CANNOT run Variable Temperature experiments currently. ONLY nominal room temperature experiments are allowed at this point. We will most probably place a different probehead in place of the current HCP-Z Gradient probehead while the current probehead is serviced.  We will try to do […]

Posted in Hardware, Spectrometer | No Comments »

UPDATE – AV300 : LOCK SYSTEM NORMAL

All good to go.  Please let us know via log book, if there is still any issues you notice. Thank you NMR Facility Manager 6/27/2018

Posted in Hardware, Spectrometer | No Comments »

ALERT ! – AV300 : LOCK MALFUNCTION WILL BE FIXED TODAY BEFORE NOON

We are aware of the Auto Lock function having issues.  In a few moments this will be addressed and an update will be given about the outcome. Stay tuned. NMR Facility Manager 6/27/2018

Posted in Hardware, Spectrometer | No Comments »

UPDATE ! AV700 : SYSTEM IS RELEASED FOR USE – PLEASE READ

The system is ready for normal use.  Nevertheless, the VT system test is still being conducted in parallel in such a way that the users’ runs are not affected.  As before, the LN2 tank you see is the source of the N2 gas, which is used as part of the troubleshoot process. The supply from […]

Posted in Hardware, Spectrometer | No Comments »

ALERT ! AV700 USERS : SYSTEM WILL BE DOWN FOR VT SYSTEM TROUBLESHOOT

Please wait further updates as to when the system will be back on line. NMR Facility Manager 6/12/2018

Posted in Hardware, Spectrometer | No Comments »

ALERT ! AV301 – SYSTEM DOWN DUE TO COMPUTER ISSUE

We are working actively to resolve the issue and will post an update once the task is competed.  Other than the ‘udrive’ mounting problem, we are also aware of the acquisition error messages that was noticed by users. Hopefully, both these error conditions will be resolved at the same time. NMR Facility Manager 6/5/2018

Posted in Hardware, Spectrometer | No Comments »

AV700 – UPDATE ON VT SYSTEM STATUS

As part of an ongoing investigation of the ultra low temperature chiller system, users are alerted to the following.  You will notice a Liquid Nitrogen Dewar sitting next to the Aluminum staircase. The N2 gas derived from this tank is used currently to run the VT system.  This setup is transparent to the way VT […]

Posted in Spectrometer, Usage | No Comments »

UPDATE : AV700 USERS – SYSTEM READY FOR USE

The BBO-1H{X}-Z gradient probe is in place now. Please Remember: After creating a dataset, do ‘edsp’ to re-initialize the new base frequency. Load the default shim file : stdbbo and then start the shimming process. NMR Facility Manager 6/4/2018

Posted in Spectrometer, Usage | No Comments »

ALERT ! AV700 USERS : IMMINENT PROBE CHANGE – Monday, 4 June ’18

The current 1H sensitive TXI-HCN probe will give way to the BBO-Z-gradient probe.  This probe is optimized for X-nuclei but also capable of 1H observe. The probe swap will occur on Monday the 4th of June 2018 forenoon. After the preliminary checks, the system should be ready for regular use by noon. Please contact me […]

Posted in Hardware, Spectrometer | No Comments »