UW CHEMISTRY NMR

Announcments & Equipment Logs

Spectrometer

UPDATE ! NEO500 – QUEUE RESTARTED

The planned software update is complete to a later version.  The queue has been restored and all the originally submitted experiments are continuing. Thank you NMR Facility Manager 7/11/2023

Posted in Software, Spectrometer, Usage | No Comments »

ALERT ! NEO500 – WILL BE OFFLINE FOR SOFTWARE MAINTENANCE TILL 5 PM

Dear Users Kindly bear with me for the last minute update, but the system will be back to running the queue by 5 PM today. I will post a confirmation once the queue is resumed. NMR Facility Manager 7/11/23

Posted in Software, Spectrometer, Usage | No Comments »

ALERT ! GG500 – iPROBE NOT READY YET

Dear Users Fresh from the expensive repair,  the iProbe is not delivering what it promised.  Although you might see Topshim seem to complete it’s job,  digging deeper, it is clear that the shimming is not at an acceptable level. Since we have a narrow window of warranty for such repairs,  it is imperative that  we […]

Posted in Hardware, Probeheads, Spectrometer, Usage | No Comments »

ALERT ! GG500 – iPROBE IS BACK – PROBE CHANGE TODAY

Dear Users We usually provide a day or so, when a probe swap is planned in a given instrument. This is usually the practice when the swap is done for benign reasons. An example will be  moving from BB (BroadBand) capability to a specialized capability such as only-19F observation. This usually gives the BB users […]

Posted in Hardware, NMR Facility Usage, Probeheads, Spectrometer, Uncategorized | No Comments »

UPDATE ! GG500 – ALL GOOD

Dear Users Topshim as well as Gradient assisted experiments are running correctly now. Tip:  For fully dueterated lock solvents, you MUST touch up the X and Y shims by hand to get the best resolution !   NMR Facility Manager 6/28/23  

Posted in Hardware, Spectrometer | No Comments »

ALERT ! GG500 – GRADIENT MALFUNCTION

Dear Users We are aware of the issue with gradients that leads to a failure of Topshim (and gradient assisted experiments as well).  We will take a look at the possible causes and provide an update as soon as we can. Stay tuned NMR Facility Manager 6/28/2023

Posted in Hardware, Spectrometer | No Comments »

UPDATE ! NEO500 – SYSTEM UP – USER ERROR CAUSED INTERRUPTION

Dear Users I will once again draw your attention to the following post that was broadcast about a month ago.  This pertains to the proper way a sample is handled with NEO500 and the SampleCase automated sample changer. Click here for that post.   To jog your memory, here is the accompanying picture Over the […]

Posted in Hardware, Spectrometer, Uncategorized, Usage | No Comments »

UPDATE – NEO500 : AUTOMATION QUEUE STARTED AGAIN

Dear Users Nothing more to add on the technical side of the instrument.  But I do have something to add as to the handling of sample and the system.  There is a ‘method to the madness’ and a ‘rationale behind a pesky insistence’, when me or Adrienne shout from the rooftop.   (As I was writing […]

Posted in Hardware, Spectrometer, Usage | No Comments »

NEO500 – CALL TO ACTION – PLEASE CLEANUP AFTER YOURSELF !

Dear NEO500 Users This is a renewed call made a few weeks back about the piling up of unused/completed NMR sample tubes, that is overwhelming the system.  See picture below :   Since we don’t have a capacity larger than 24 sample tubes,  we really need you to be on top of your cleanup act, […]

Posted in Hardware, Spectrometer, Usage | No Comments »

ALERT ! GG500 – POSSIBLE DAMAGE TO iPROBE – TXO PROBE IS IN ITS PLACE NOW

Hello All Following an unfortunate incident of a user dropping the sample tube into the magnet bore without a spinner,  it turned out that the sample tube broke inside the new iProbe probehead.  Being a mint condition probe, which also belongs to the latest generation, it will need careful handling in assessing the extent of […]

Posted in Hardware, Probeheads, Spectrometer | No Comments »