UW CHEMISTRY NMR

Announcments & Equipment Logs

Spectrometer

AV301 UPDATE : LINESHAPE OPTIMIZED

The lineshape distortions following the probe swap are addressed now.  Users are requested to load the default shim file ‘stdtxd’ before they run their NMR.  It is important to note that you must shim at the minimum the Z, Z2, X, Y gradients to get an acceptable lineshape.  The default shim file only guarantees the optimum […]

Posted in Spectrometer, Usage | No Comments »

ALERT ! AV500 UPDATE : UWNetid FUNCTIONAL – AGAIN

Users are requested to note that they can user their UWNetid login as before to operate the NMR spectrometer. A new operating system platform has been installed to address the vexing problem of  Netid login failure. This transition should provide trouble free UWNetid login as well as a smooth execution of all the Topspin automation […]

Posted in Hardware, Software, Spectrometer, Usage | No Comments »

ALERT : AV500 PROBE CHANGE

Users are requested to take note that the BBO – X{1H} probe will go in by the afternoon of Thursday the 18th of July’13.  The system should be ready for regular use by Friday the 19th ’13.  Any change in the schedule will be notified duly.

Posted in Hardware, Spectrometer, Usage | No Comments »

AV301 UPDATE : PROBE CHANGE ALERT

The repaired 19F {1H, 13C} probe will soon be shipped from the manufacturer.  In approximately a week’s time this probe will take the place of the current double resonance probe.  Users are requested to take note.

Posted in Hardware, Spectrometer | No Comments »

AV500 : IMMINENT PROBE CHANGE

The current TXO-1H,19F and 13C  probe has been identified with a inter-channel cross talk problem.  The probe is functional in and around room temperature,  but for those users doing  low temperatures, they will find it difficult to ‘wobb’ the probe at these temperatures. The TXO probe will be replaced in approximately a week’s time with […]

Posted in Hardware, Spectrometer | No Comments »

AV500 UPDATE : PROPER SETUP OF EXPERIMENTS

Following the reconfiguration of the Lock system, users need to observe the following procedure to get correct results. If you are copying an old data set to start a new run, please run the  edasp command.   You will see a graphical window similar to the following : Click on the Save button to exit. Your […]

Posted in Software, Spectrometer, Usage | No Comments »

AV500 : LOCK UPDATE

Users had noted that the intermittent lock issue was back again.  A careful scrutiny was made and a needed configuration change was made to solve this problem.  The system should lock on all solvents without any error now.  If it is otherwise, please do note the same in the Log Book along with any other […]

Posted in Hardware, Software, Spectrometer | No Comments »

AV500 UPDATE : LOCK ISSUE FIXED

A possible power fluctuation over the weekend led to the disrupted lock and acquisition conditions of the instrument. These are now resolved and users can continue with normal operation of the instrument.

Posted in Hardware, Spectrometer | No Comments »

AV500 : AUTOMATION SCRIPTS COMPILATION ISSUES

There is a software glitch that is preventing the proper compilation of several automation scripts, including the commonly used ones such as ‘iexpno’ or ‘multizg_vd’.  We are working on this and I will post an update once this issue is resolved.

Posted in Software, Spectrometer | No Comments »

ALERT : PRINTER IS FUNCTIONAL AGAIN

Users can either print directly from Topspin or use the ‘plot’ program to direct print requests to the Laserjet printer, as before. Please keep facility staff informed if you notice any anomaly.

Posted in Hardware, Spectrometer | No Comments »

Item Categories

Archives