UPDATE ! GG500 – AUTOMATION QUEUE RESUMED

You can start submitting samples.  Sample inject/eject issue is addressed. NMR Facility Manager 7.30.25

Posted in Spectrometer, Usage | No Comments »

ALERT ! GG500 – SYSTEM DOWN DUE TO SAMPLE HANDLING ISSUE

The sample eject/inject problem, led to the crash of the automation queue this morning. The system will be down until further notice to identify and remedy the issue. I will post an update once the queue is resumed. NMR Facility Manager 7.30.2025

Posted in Hardware, Spectrometer | No Comments »

UPDATE – NEO500 – PROBE IS FULLY FUNCTIONAL WITH TOPSHIM

Dear Users The probe is optimized for different lock solvents that should make shimming with Topshim quick and easy. I have created individual shim files that are the optimal starting points for the most often used lock solvents. The files are named as below : txo.water (for aqueous samples, including those in D2O) txo.acteone txo.cdcl3 txo.c6d6 txo.dmso […]

Posted in Probeheads, Spectrometer, Usage | No Comments »

UPDATE ! NEO500 – PROBE CHANGED TO TXO-19F{1H,13C} – PLEASE NOTE

Dear Users The previous TBI probe had to be removed for a service operation, and I have placed the TXO-19F PROBE for the present as an alternative.  Please note the following : Nuclei : 19F, 1H and 13C You can run 1H decoupled 19F experiments To switch between 19F and 13C, a cable swap is needed […]

Posted in Probeheads | No Comments »

REMINDER ! PLEASE CLEAN UP LEFT OVER SAMPLES !

Dear Users After 12 noon today, all the leftover samples in the buffer racks will be removed and disposed off. Please act now and collect those that are important to you.  NMR Facility Manager 7.25.2025

Posted in NMR Facility Usage | No Comments »

GG500 : ALL GOOD – AUTOMATION QUEUE IS UP AND RUNNING

Frozen interface is fixed.  The original queue is resumed.    You can submit samples as usual. NMR Facility Manager 7.25.2025

Posted in Spectrometer, Usage | No Comments »

UPDATE : GG500 DATA AND PHOENIX

We are aware of the issue in accessing GG500 data (ONLY) via the Phoenix server. This is being looked into.  We will post a message once it is up again. NMR Facility Manager 7.18.25

Posted in Datasets, Host Computer, Operating System | No Comments »

UPDATE ! GG500 – AUTOMATION QUEUE RESUMED – CAN SUBMIT SAMPLES

Dear Users An improved automatic shimming algorithm via IconNMR is now in place. This should help, but it is part of the process that I need to complete, where solvent specific files need to be updated.    That work will take place in coming days.   Your resolution should be better, but if you see increased […]

Posted in Software, Spectrometer | No Comments »

ALERT ! GG500 – AUTOMATION PAUSED TILL NOON

Dear Users To address the repeated observations about non-optimal line shapes and shims, as well as to take care of few pending software tasks, the automation queue is stopped now.    The instrument will NOT be available for submitting samples until then (please always consult the instrument reservation calendar, before proceeding to submit samples). At […]

Posted in Hardware, Software, Spectrometer | No Comments »

ALERT ! NEO500 – TOPSHIM MALFUNCTIONING

Topshim is not performing optimization although the software goes through the motions.  We are looking into it and will give an update as and when feasible. The shim system  is alive i.e. you can shim the sample by hand if all else fails. We will keep you updated. NMR Facility 7.11.25

Posted in Software, Spectrometer, Usage | No Comments »