UW CHEMISTRY NMR

Announcments & Equipment Logs

UPDATE ! : NMR RESERVATION SYSTEM BACK TO NORMAL

Please let us know if you have issues reserving time for any of the instruments.  The tests so far produced desired results. NMR Facility Manager 12/3/18 10.32 am

Posted in Spectrometer, Usage | No Comments

ALERT ! : NMR RESERVATION SYSTEM MALFUNCTION

We are aware that you are not able to reserve NMR time via the usual webpage front end. We are looking into the reservation server as we speak. I will post an update as soon as the problem is resolved.  If it turns out that the problem will take longer than 30 minutes resolve, we […]

Posted in Spectrometer, Usage | No Comments

ALERT ! AV500 – NEW TBI PROBE IS READY FOR USE

Triple Resonance probe TBI – 1H, 13C {X-BB}-Z gradient probe is ready for use. STANDARD SHIM SET :  Please start with ‘rsh stdtbi’  and proceed with Topshim.   Of course, you have to lock onto your solvent first. Few highlights about the probe: Here is the front plate view that is self-explanatory   View of the […]

Posted in Uncategorized | No Comments

ALERT ! AV500 – PROBE SWAP – CHANGE IN SCHEDULE

The original schedule of Probe swap in this instrument has been advanced to today/tomorrow.  Part of the motivation for this is the (good) news that the REVIVED DRX499 is almost ready for full scale deployment within a few days. We are placing a new probehead called TBI-1H,13C {X} – Z gradient in AV500. This probe […]

Posted in Hardware, Spectrometer | No Comments

IMPORTANT NOTE : UPCOMING TRAINING ON MANUAL SHIMMING AND TUNE/MATCH

Currently, we have only two spectrometers equipped with the ATMA facility and Topshim functionality.  Decidedly, both these features take the drudgery out of routine NMR run, especially short ones. If you are someone who come to totally rely on these features for your NMR runs,  you do have to face the following cons : You […]

Posted in Spectrometer, Usage | No Comments

ALERT ! AV500 : IMMINENT PROBE CHANGE NEXT WEEK

The BBO probe will be installed and tested and hopefully be ready by the forenoon of 29th Nov ’18, Thursday. Please take note of this and plan accordingly. NMR Facility Manager 11/29/2018

Posted in Hardware, Spectrometer | No Comments

AV700 and DRX499 UPDATE : PLEASE READ – SOLUTIONS TO SOLIDS TRANSITION – PLANS

The AV700 NMR spectrometer will be receiving a new Solid State MAS NMR probehead within the next few weeks.  I will announce the finer details of this piece of equipment later. Please note that, currently the instrument is transitioned to solid state NMR mode to confirm its functionality before the new probehead is installed and […]

Posted in Hardware, Spectrometer, Usage | No Comments

ALERT ! AV500 – TOPSHIM GLITCH

Topshim may tend to fail for low sensitivity lock solvent such as CDCl3, but it will work fine with solvents such as C6D6, CD3CN or MeOD-d4.   We will be looking to resolve this by engaging the instrument in an intermittent fashion to minimize down time. An update will be posted once the issue is fully […]

Posted in Hardware, Spectrometer | No Comments

UPDATE : PHOENIX SERVER – TEMPORARY GLITCH RESOLVED

Some of you might have noticed that the FTP site was blacked out from 11.30 am.  The issue was identified and resolved. Please note that the DRX499 won’t appear in this list currently due to the repair/migration process that is underway with that instrument. NMR Facility Manager 10/17/18

Posted in Datasets, Host Computer | No Comments

ALERT ! AV500 – PROBE CHANGED TO TXO- 1H {19F, 13C}

Since the existing BBI probe had suffered a breakage in the VT dewar assembly, we were compelled to abruptly change the probehead to TXO- 19F probe. There was an original plan to do this probe swap by next week, in any case. Once the probe vitals are checked it will be released for regular use. […]

Posted in Hardware, Spectrometer | No Comments