UPDATE : AV300 – PROGRESS WITH UDRIVE MIGRATION – BUT NOT READY YET
A few more lose ends to tie up before you will be ready to access the UDRIVE, similar to AV301. But the needed work will be done remotely without disrupting the regular use of the spectrometer. I will post another heads up message when we say it’s ready. In the interim, your data collection protocol […]
Posted in Software, Spectrometer, Usage | No Comments
ALERT ! AV300 – UDRIVE UPGRADE SCHEDULED FOR TOMORROW
The Operating System and associated components will be upgraded starting tomorrow morning 9 am i.e. Tuesday, 31st of July ’18. Assuming that everything goes well, the interface you will see from 12 noon will be similar to the one on AV301. Also note that the data from then on will be directly written into your […]
Posted in Spectrometer, Usage | No Comments
UPDATE – AV700 : SYSTEM OPEN FOR USE
Alternative arrangement for VT control is in place. Please post a message in the log book, if you notice abnormal behavior. Thank you for your cooperation. NMR Facility Manager 7/20/2018
Posted in Spectrometer, Usage | No Comments
ALERT – AV700 : SYSTEM DOWN DUE TO VT ISSUES
By now familiar but ongoing issue with the VT cooling system is forcing an interruption once again today. We will work on an alternative and I am hopeful that the instrument can be released for regular use by tomorrow. Please look for further updates. NMR Facility Manager 7/19/2018
Posted in Hardware, Spectrometer | No Comments
ALERT ! AV500 – PROBE HAS BEEN CHANGED
Since I discovered today morning that the VT dewar in the probe is compromised, I had to replace the BBI probe with the a different probe : Current probe head : TXI- 1H {13C, 15N} – Z gradient This is a triple resonance probe that is capable of handling 1H, 13C and 15N detection only. […]
Posted in Hardware, Spectrometer | No Comments
UPDATE ! AV500 – SYSTEM NORMAL WITH BBI PROBE IN PLACE
NEW PROBEHEAD IN PLACE ! CURRENT PROBE : BBI 1H {X} – Z gradient DEFAULT SHIM SET : stdbbi Temperature range : -100 C to +70 C (for the former, special low T setup is needed. Contact for further details) PLEASE USE TOPSHIM FOR GETTING THE BEST RESOLUTION AND LINESHAPE Questions/Comments/Help ? : Please contact […]
Posted in Hardware, Spectrometer | No Comments
ALERT ! AV500 – POSSIBLE PROBE CHANGE – VT DEWAR DAMAGED
The VT dewar inside the probe has been compromised and so you CANNOT run Variable Temperature experiments currently. ONLY nominal room temperature experiments are allowed at this point. We will most probably place a different probehead in place of the current HCP-Z Gradient probehead while the current probehead is serviced. We will try to do […]
Posted in Hardware, Spectrometer | No Comments
UPDATE – AV300 : LOCK SYSTEM NORMAL
All good to go. Please let us know via log book, if there is still any issues you notice. Thank you NMR Facility Manager 6/27/2018
Posted in Hardware, Spectrometer | No Comments
ALERT ! – AV300 : LOCK MALFUNCTION WILL BE FIXED TODAY BEFORE NOON
We are aware of the Auto Lock function having issues. In a few moments this will be addressed and an update will be given about the outcome. Stay tuned. NMR Facility Manager 6/27/2018
Posted in Hardware, Spectrometer | No Comments
UPDATE ! AV700 : SYSTEM IS RELEASED FOR USE – PLEASE READ
The system is ready for normal use. Nevertheless, the VT system test is still being conducted in parallel in such a way that the users’ runs are not affected. As before, the LN2 tank you see is the source of the N2 gas, which is used as part of the troubleshoot process. The supply from […]
Posted in Hardware, Spectrometer | No Comments