UW CHEMISTRY NMR

Announcments & Equipment Logs

Usage

AV800 UPDATE : INSTRUMENT FUNCTIONAL

Users are welcome to contact me for NMR time during the walk-on period on the 800 instrument.  The next slot begins on Monday, the 8th of April ’13.

Posted in Spectrometer, Usage | No Comments »

AV301 UPDATE : INSTRUMENT READY FOR USE (AGAIN…)

Users !  Please take a few moments to focus on sample insertion sequence, confirm that the sample is seated properly in the NMR magnet and then start zipping off with your experiments.  Remember, one person’s haste can cost lot of lost instrument time for the entire user base. Thank you for your cooperation.

Posted in Hardware, Spectrometer, Usage | No Comments »

AV500 : INSTRUMENT READY FOR USE

Users can start booking time on this instrument. The probe is : 1H {19F, 13C} – Z gradient. Temperature range (without LN2 evaporator) : +10 C to +70 C. Standard Shim File :  stdtxo

Posted in Hardware, Spectrometer, Usage | No Comments »

ALERT : AV301 DOWN DUE TO USER ERROR

A user has dropped a NMR sample tube without the spinner and lift air, into the magnet bore.  As a result the spectrometer is not immediately useable.  The issue will be resolved by Tuesday, April, 2nd and a follow up will be posted here.

Posted in Hardware, Spectrometer, Usage | No Comments »

ALERT ! AV301 UPDATE : SYSTEM READY FOR USE

The AV301 instrument is ready for use after a long hiatus. It will be hosting the Automated BBI probe that completely eliminates the need to tune and match by hand.   For any given experiment or parameter set, you need to just enter the command “atma”  on the command line.  The ‘wobb’ will be automatically performed […]

Posted in Software, Spectrometer, Usage | No Comments »

AV301 : PROBE HEAD PROBLEM – SYSTEM DOWN

A possible breakage inside the probe makes the system unusable as of now.  The matter is being looked into.  An alternative solution will be provided as soon as feasible.

Posted in Hardware, Spectrometer, Usage | No Comments »

AV301 UPDATE : BROKEN PARTS IN PROBEHEAD

Most probably due to a combination of poor quality NMR tubes that were spun and a less than careful sample positioning in the sample spinner,  by various users,  the expensive quartz insert glass tubes inside the probe have been shattered.  All the woes of the past few days, with the sample seating, difficulty in spinning […]

Posted in Hardware, Spectrometer, Usage | No Comments »

DRX499 UPDATE : lineshape and standard shims

Although more work needs to be done, the reported high order shim distortion has been removed and the shim set is eminently useable. Users should get back to me if they find specific issues in shimming with respect to their samples.   Please use the default start up shim set : stdbbi before you attempt your […]

Posted in Software, Spectrometer, Usage | No Comments »

FACILITY UPDATE : Help for Users – contacting facility manager

With the departure of Paul Miller from the NMR Facility to the new position,  users are requested to direct all queries related to day to day NMR operations to the Facility Manager,  Rajan Paranji i.e. the author of this note.   I can be reached via the following means : Phone : 206 685 2581 […]

Posted in NMR Applications, Usage | No Comments »

CAUTION : DISRUPTION CAUSED BY USER REBOOT

Users are strongly reminded that,  it is best to avoid the temptation of rebooting the computer,  when they ‘think’ that that will remedy a given situation.   The requirement to reboot a computer to take care of any issue is quite rare and any problems that are faced by users require much simpler measures such as […]

Posted in Host Computer, Operating System, Usage | No Comments »