ALERT – NMRJUICER IS DOWN

The authentication mechanism that allows UWNetid logins is not functional at the moment and we are looking into it.  Until this is resolved, the workstation is not usable.  Sorry for hte inconvenience.  An update will be posted once the problem is fixed.

Posted in Host Computer, Operating System | No Comments

ALERT – DRX499 : WALK ON TIMING UPDATE

To bring the two 500 MHz instruments on par and to ease the load on the AV500 spectrometer, that is being heavily booked of late,  users are informed that the walk-on duration on DRX499 is extended to a 3 hour limit from the current 1 hour limit. This should help users significantly. For instance one […]

Posted in Spectrometer, Usage | No Comments

AV301 – UPDATE : LINESHAPE DISTORTION

We are aware of this issue and looking into it. Preliminary investigation has ruled out the probehead to be the immediate cause and we are in the process of testing other components.  In the meanwhile,  users are encouraged to use the pulse program zg30 in place of the usual zg experiment to record the spectra.  […]

Posted in Hardware, Spectrometer | No Comments

ALERT ! AV301 : PROBE CHANGE TO BBI – READY FOR USE ON 7 SEPT, TUE, EVENING

The ATMA  BBI probe that is capable of computer controlled tuning/matching will take the place of the current TXD-19F probe. The probe should be ready for regular use by 4.00 pm, Tuesday the 7th of September i.e. tomorrow.  All the TOPSPIN user interfaces will have the Auto Wobb button that will help you automatically tune […]

Posted in Uncategorized | No Comments

ALERT – AV500 : DEUTERIUM GRADIENT SHIMMING NON-FUNCTIONAL

A hardware board malfunction makes the 2H Topshim non-functional.  Repair attempts are in progress with the faulty circuit board.  Users can still use Topshim 1D and 3D for proteo-solvents and aqueous sample preps.  Update will be posted in due course.

Posted in Hardware, Spectrometer | No Comments

UPDATE ! – DRX499 – NEW COMPUTER INSTALLATION COMPLETE

The topspin environment is functional with the spectrometer, running on the new computer.  Compilation of Topspin automation scripts is not yet up and running and this will be addressed in the coming days.  But the spectrometer is usable in a normal fashion. Please keep the facility staff updated if you notice anything worthwhile.  If your […]

Posted in Uncategorized | No Comments

UPDATE ! DRX499 – NEW COMPUTER REPLACEMENT IN PROGRESS

The old computer suffered an irrecoverable hardware failure but the storage disks seemed to have survived.  The replacement PC for this instrument was almost ready and we are accelerating the preparation of the same. The transfer of existing datasets and other configurations from the old disks do take some time. It is estimated that the […]

Posted in Host Computer, Operating System | No Comments

ALERT ! DRX499 : COMPUTER DOWN

A hardware issue with the computer has made the system unusable.  We are trying the revive the system and an update will be posted in due course.

Posted in Host Computer | No Comments

UPDATE : ALL FACILITY INSTRUMENTS ARE OPERATIONAL

All instruments tested to be stable and in normal operational mode.  The FTP server is hosting the data trees of all instruments, as expected.

Posted in Hardware, Spectrometer | No Comments

ALERT ! FACILITY POWER SHUTDOWN TOMORROW, Sept. 5th

As announced earlier, the NMR facility instruments will be shutdown by 3.30 pm tomorrow in anticipation of a scheduled power shut down to the NMR lab i.e. Room:37, Bagley Hall by early morning on Saturday the 6th September. The power shut down is announced to last until 3.00 pm on Saturday. The instruments will be […]

Posted in Hardware, Spectrometer | No Comments