ALERT ! AV300 – IMMINENT PROBE CHANGE
The ATMA probe is seen to have issues while tuning/matching the 1H channel. All symptoms point to the necessity for the probe to be pulled out and serviced, soon. I am giving the heads up now that this probe might come out at a short notice on one of the days this week and a […]
Posted in Hardware, Spectrometer, Usage | No Comments »
UPDATE ! AV301 – PROBE IS SHIMMED UP AND READY
The MANUAL BBO PROBE is ready for use. Please use “rsh stdbbo” to start from a reliable shim set before you shim up on your own. NOTE : THIS PROBE CANNOT DO TOPSHIM OR ATMA. Both ‘wobb’ and shimming should be done manually. Please get in touch if you need help or clarification NMR Facility […]
Posted in Hardware, Spectrometer, Usage | No Comments »
ALERT ! AV301 – UDRIVE – MOVING TO PHASE 2 TOMORROW – Wed, 6 Jul 2017
The default data branch /opt/topspin/<user>/nmr will NO LONGER be visible within AV301 Topspin, starting tomorrow, sometime after 9 am. The data written until that point will be available as a static/frozen file tree via the Phoenix FTP server as of now. Please contact me if you have concerns. NMR Facility Manager 7/5/2017
Posted in Software, Spectrometer, Usage | No Comments »
ALERT – AV500 : BASELINE NOISE DETECTED
Several users have seen spikes in the baseline of 1H NMR spectra. Unless sample concentration is very low, the relative intensities of solute peaks are large enough to identify compared to these spikes. So, as of today, users can continue the runs for which they have already booked time. The instrument will be taken down […]
Posted in Spectrometer, Usage | No Comments »
UPDATE – DRX499 : SYSTEM WILL BE READY ON MONDAY, 24 Apr
I am acutely aware of the long down time on this instrument and I convey my sincere gratitude for your patient cooperation all along. The good news is that, the system is brought to a stable and reliable state as I write this. Last but not least, the shim up needs to be completed before […]
Posted in Hardware, Software, Spectrometer, Usage | No Comments »
DRX499 UPDATE ! – SYSTEM IS READY FOR USE.
Please note that we might have to touch up the shims once more down the road but as of now the instrument is ready for regular use. Please keep us posted if you notice anything out of the ordinary. We encourage you to use the online logbook to effectively communicate what you observe, as and […]
Posted in Hardware, Spectrometer, Usage | No Comments »
UW IT’s DATA STORAGE SYSTEM FOR NMR DATA – udrive – PART 2
We need volunteers to try out this new data storage paradigm, initially via the AV301 instrument. PLEASE COME FORWARD !! Your current data storage and retrieval method via FTP server will NOT be affected during the testing period. If you would like to help with the effort, please contact me or Adrienne and thank you […]
Posted in Datasets, Software, Uncategorized, Usage | No Comments »
ATTENTION ALL USERS ! : NMR LAB RM: 37 ACCESS RESTRICTION THIS WEEK
Facilities Works will redo the flooring of the corridor in Bagley Hall where the NMR lab is located on the following days this week : Tuesday, Wednesday and Thursday. This operation will last from 5.30 am until 8.30 am on each of these days. During this time, no foot traffic will be allowed on the […]
Posted in Spectrometer, Uncategorized, Usage | No Comments »